Autoclave cum Bung processor having the chamber size 900×900×1500mm and is made up of SS 316L provided with 3 validation ports having 7 Nos of probes in Each validation port. Vacuum Break filter 5 inches long Having 0.2 micron porosity is provided Bung & flip off carriage made of SS 316L, 2 Nos.

trolley made of SS 304L for keeping the components in autoclave cum bung processor provided during sterilization. The Autoclave Cum Bung Processor will be qualified after validating (As per the methods outlined in this Protocol) the equipment for desired performance and its ability to sterilize different components and/or loads at the set parameters & set loading patterns, repeatedly & consistently.· Loaded Chamber heat penetration studies (3 trials) for each sterilization load of fixed loading pattern, with temperature mapping probes inside the innermost possible layer of the load subjected for sterilization.

validating an autoclave-71validating an autoclave-62

Validating an autoclave

Approved analytical methods for testing the samples collected during the processing C.

The impact analysis of the equipments shall be recorded in the summary sheet. The installation and operational qualification of the equipment shall be successfully completed before the execution of the performance qualification. All the deficiencies and discrepancies related to the equipment which affect the product quality and corrective action taken shall be recorded in the appropriate section of the protocol. The analytical test results and other reports related with the equipment shall be attached with the performance qualification of the equipment and finally verified.

CMI is a leading provider of validation and decontamination services to a whole host of industries and sectors, including universities, research facilities, food production, clinical, hospitals, dentists, vets and pharmaceutical organisations.

As one of the largest and longest-serving companies within the sterile services sector, we pride ourselves on delivering the highest possible standard of service, taking an honest, trustworthy approach to everything we do.

I was delighted to be introduced to CMI Healthcare in 2015.

Prior to that, I had become very frustrated with the service available to dental surgeries for servicing and validating decontamination room equipment.

Using saturated steam, the same spores are killed in just five minutes at 121°C, proving that moist heat is more effective than dry heat.

To be effective against spore forming bacteria and viruses, autoclaves need to: The efficiency of the sterilization process depends on two major factors. the time microbes must be exposed to at a particular temperature before they are all dead.